Search in Xamin or Browse... |
AEGISX - AEGIS-X Chandra Extended Groth Strip X-Ray Point Source Catalog |
HEASARC Archive |
AEGIS-X: the Chandra Deep Survey of the Extended Groth Strip Laird E.S., Nandra K., Georgakakis A., Aird J.A., Barmby P., Conselice C.J., Coil A.L., Davis M., Faber S.M., Fazio G.G., Guhathakurta P., Koo D.C., Sarajedini V., Willmer C.N.A. <Astrophys. J. Suppl. 180, 102-116 (2009) =2009ApJS..180..102L
Source_ID
The X-ray source identifier using the 'egs' prefix for Extended
Groth Strip and a source number in order of increasing J2000.0 Right
Ascension.
Field_ID
The field identifier for the X-ray source, which indicates the
individual field in which the source was detected (see Section 2.1 of the
reference paper for further information on the field definitions).
Name
The Chandra X-ray Observatory (CXO) X-ray designation, using the
standard 'CXOU J' prefix and the J2000.0 equatorial source position.
RA
The Right Ascension of the Chandra X-ray source in the selected equinox.
This was given in J2000.0 decimal degrees to an accuracy of 10-6 degrees
(0.0036 arcseconds) in the original table. These coordinates have been shifted
to agree with the Sloan Digital Sky Survey (SDSS) reference frame of the
DEEP2 images: the positional offsets applied to each field are listed in Table
3 of the reference paper.
Dec
The Declination of the Chandra X-ray source in the selected equinox.
This was given in J2000.0 decimal degrees to an accuracy of 10-6 degrees
(0.0036 arcseconds) in the original table. These coordinates have been shifted
to agree with the Sloan Digital Sky Survey (SDSS) reference frame of the
DEEP2 images: the positional offsets applied to each field are listed in Table
3 of the reference paper.
LII
The Galactic Longitude of the Chandra X-ray source.
BII
The Galactic Latitude of the Chandra X-ray source.
Error_Radius
The X-ray source one-sigma positional error, in arcseconds.
Off_Axis
The X-ray source off-axis angle, in arcminutes.
FB_Counts
The X-ray source full-band (0.5 - 7 keV) counts.
Counts are given regardless of whether a source was detected in the band.
FB_Bck_Counts
The expected full-band (0.5 - 7 keV) background counts
within the X-ray source extraction region.
SB_Counts
The X-ray source soft-band (0.5 - 2 keV) counts.
Counts are given regardless of whether a source was detected in the band.
SB_Bck_Counts
The expected soft-band (0.5 - 2 keV) background counts
within the X-ray source extraction region.
HB_Counts
The X-ray source hard-band (2 - 7 keV) counts.
Counts are given regardless of whether a source was detected in the band.
HB_Bck_Counts
The expected hard-band (2 - 7 keV) background counts
within the X-ray source extraction region.
UHB_Counts
The X-ray source ultra-hard-band (4 - 7 keV) counts.
Counts are given regardless of whether a source was detected in the band.
UHB_Bck_Counts
The expected ultra-hard-band (4 - 7 keV) background counts
within the X-ray source extraction region.
Detect_Bands
The bands in which the source is detected with Poisson
false-detection probability < 4 x 10-6, where the bands are full (f),
soft (s), hard (h), and ultra-hard (u).
Min_Detect_Prob
The lowest false detection probability found for the X-ray
source in the four energy bands; probabilities lower than 10-8 are quoted
as 10-8.
Source_Flag
This flag parameter is set to 'a' if the Bayesian X-ray fluxes
in the detected bands were calculated from the 70% encircled energy fraction
(EEF) rather than the usual 90% EEF.
Bayes_FB_Flux_Limit
This parameter is set to '<' if the associated flux is
an upper limit rather than a measured value. The limits are 1-sigma, or 68%,
upper limits.
Bayes_FB_Flux
The standard full-band (0.5 - 10 keV) X-ray source flux, in erg s-1 cm-2,
calculated using the Bayesian method described in Section 3.3 of the
reference paper, which corrects for the Eddington bias. In three cases
(source_id values egs_0367, egs_0457, and egs_0633), sources that were
significantly detected in a band had best estimate fluxes of zero, using the
Bayesian method. This discrepancy arises due to the different EEFs used for
the photometry (90% EEF) and for the detection (70% EEF). In these cases, the
authors use source and background counts corresponding to the 70% EEF area to
calculate the fluxes in the detected bands. All the fluxes have not been
corrected for Galactic or intrinsic source absorption. To correct for
Galactic absorption the full- and soft-band fluxes should be increased by 2%
and 4.2%, respectively. The corrections to the hard and ultra-hard fluxes are
negligible.
Bayes_FB_Flux_Pos_Err
The upper 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
Bayes_FB_Flux_Neg_Err
The lower 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
Bayes_SB_Flux_Limit
This parameter is set to '<' if the associated flux is
an upper limit rather than a measured value. The limits are 1-sigma, or 68%,
upper limits.
Bayes_SB_Flux
The standard soft-band (0.5 - 2 keV) X-ray source flux, in erg s-1 cm-2,
calculated using the Bayesian method described in Section 3.3 of the
reference paper, which corrects for the Eddington bias. In three cases
(source_id values egs_0367, egs_0457, and egs_0633), sources that were
significantly detected in a band had best estimate fluxes of zero, using the
Bayesian method. This discrepancy arises due to the different EEFs used for
the photometry (90% EEF) and for the detection (70% EEF). In these cases, the
authors use source and background counts corresponding to the 70% EEF area to
calculate the fluxes in the detected bands. All the fluxes have not been
corrected for Galactic or intrinsic source absorption. To correct for
Galactic absorption the full- and soft-band fluxes should be increased by 2%
and 4.2%, respectively. The corrections to the hard and ultra-hard fluxes are
negligible.
Bayes_SB_Flux_Pos_Err
The upper 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
Bayes_SB_Flux_Neg_Err
The lower 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
Bayes_HB_Flux_Limit
This parameter is set to '<' if the associated flux is
an upper limit rather than a measured value. The limits are 1-sigma, or 68%,
upper limits.
Bayes_HB_Flux
The standard hard-band (2 - 10 keV) X-ray source flux, in erg s-1 cm-2,
calculated using the Bayesian method described in Section 3.3 of the
reference paper, which corrects for the Eddington bias. In three cases
(source_id values egs_0367, egs_0457, and egs_0633), sources that were
significantly detected in a band had best estimate fluxes of zero, using the
Bayesian method. This discrepancy arises due to the different EEFs used for
the photometry (90% EEF) and for the detection (70% EEF). In these cases, the
authors use source and background counts corresponding to the 70% EEF area to
calculate the fluxes in the detected bands. All the fluxes have not been
corrected for Galactic or intrinsic source absorption. To correct for
Galactic absorption the full- and soft-band fluxes should be increased by 2%
and 4.2%, respectively. The corrections to the hard and ultra-hard fluxes are
negligible.
Bayes_HB_Flux_Pos_Err
The upper 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
Bayes_HB_Flux_Neg_Err
The lower 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
Bayes_UHB_Flux_Limit
This parameter is set to '<' if the associated flux is
an upper limit rather than a measured value. The limits are 1-sigma, or 68%,
upper limits.
Bayes_UHB_Flux
The standard ultra-hard-band (5 - 10 keV) X-ray source flux, in erg s-1
cm-2, calculated using the Bayesian method described in Section 3.3 of the
reference paper, which corrects for the Eddington bias. In three cases
(source_id values egs_0367, egs_0457, and egs_0633), sources that were
significantly detected in a band had best estimate fluxes of zero, using the
Bayesian method. This discrepancy arises due to the different EEFs used for
the photometry (90% EEF) and for the detection (70% EEF). In these cases, the
authors use source and background counts corresponding to the 70% EEF area to
calculate the fluxes in the detected bands. All the fluxes have not been
corrected for Galactic or intrinsic source absorption. To correct for
Galactic absorption the full- and soft-band fluxes should be increased by 2%
and 4.2%, respectively. The corrections to the hard and ultra-hard fluxes are
negligible.
Bayes_UHB_Flux_Pos_Err
The upper 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
Bayes_UHB_Flux_Neg_Err
The lower 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
FB_Flux_Limit
This parameter is set to '<' if the associated flux is
an upper limit rather than a measured value. The limits are 99% upper limits,
notice, not 68% ones as for the Bayesian fluxes.
FB_Flux
The observed-frame standard full-band (0.5 - 10 keV) X-ray source flux, in
erg s-1 cm-2, obtained using the 'classical method'. All the fluxes have
not been corrected for Galactic or intrinsic source absorption. To correct
for Galactic absorption the full- and soft-band fluxes should be increased by
2% and 4.2%, respectively. The corrections to the hard and ultra-hard fluxes
are negligible.
FB_Flux_Pos_Err
The upper 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
FB_Flux_Neg_Err
The lower 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
SB_Flux_Limit
This parameter is set to '<' if the associated flux is
an upper limit rather than a measured value. The limits are 99% upper limits,
notice, not 68% ones as for the Bayesian fluxes.
SB_Flux
The observed-frame standard soft-band (0.5 - 2 keV) X-ray source flux, in erg
s-1 cm-2, obtained using the 'classical method'. All the fluxes have not
been corrected for Galactic or intrinsic source absorption. To correct for
Galactic absorption the full- and soft-band fluxes should be increased by 2%
and 4.2%, respectively. The corrections to the hard and ultra-hard fluxes are
negligible
SB_Flux_Pos_Err
The upper 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
SB_Flux_Neg_Err
The lower 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
HB_Flux_Limit
This parameter is set to '<' if the associated flux is
an upper limit rather than a measured value. The limits are 99% upper limits,
notice, not 68% ones as for the Bayesian fluxes.
HB_Flux
The observed-frame standard hard-band (2 - 10 keV) X-ray source flux, in erg
s-1 cm-2, obtained using the 'classical method'. All the fluxes have not
been corrected for Galactic or intrinsic source absorption. To correct for
Galactic absorption the full- and soft-band fluxes should be increased by 2%
and 4.2%, respectively. The corrections to the hard and ultra-hard fluxes are
negligible
HB_Flux_Pos_Err
The upper 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
HB_Flux_Neg_Err
The lower 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
UHB_Flux_Limit
This parameter is set to '<' if the associated flux is
an upper limit rather than a measured value. The limits are 99% upper limits,
notice, not 68% ones as for the Bayesian fluxes.
UHB_Flux
The observed-frame standard ultra-hard-band (5 - 10 keV) X-ray source flux,
in erg s-1 cm-2, obtained using the 'classical method'. All the fluxes
have not been corrected for Galactic or intrinsic source absorption. To
correct for Galactic absorption the full- and soft-band fluxes should be
increased by 2% and 4.2%, respectively. The corrections to the hard and
ultra-hard fluxes are negligible
UHB_Flux_Pos_Err
The upper 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
UHB_Flux_Neg_Err
The lower 1-sigma error in the associated flux
parameter, in erg s-1 cm-2.
Bayes_HR
The X-ray source hardness ratio calculated using the Bayesian
method.
Bayes_HR_Pos_Err
The upper 1-sigma error in the Bayesian hardness ratio.
Bayes_HR_Neg_Err
The lower 1-sigma error in the Bayesian hardness ratio
Hardness_Ratio
The X-ray source hardness ratio HR calculated using the
classical method. For sources only detected in the full band, and with upper
limits in both hard and soft bands, the classical HR cannot be determined and
is set to -99.00.
Quality_Flag
This parameter contains a flag for the quality of the X-ray
photometry. A flag value of '1' indicates the presence of a nearby source that
may be contaminating the photometry. A flag value of '2' indicates that another
source was detected with the 90% EEF and that the photometry is likely heavily
contaminated and the source position uncertain (see Section 3.3 of the
reference paper). All other sources have a flag value of 0'.
Opt_IR_Match_Flag
This parameter can contain a coded flag for the
source matching details as follows:
a = Bright, resolved galaxies that are clearly present in the CFHTLS i' imaging but have been excluded from CFHTLS catalog for unknown reason. b = Bright IRAC sources, without secure optical counterpart listed in the table, that have been excluded from Figure 9. Clear, very bright optical counterparts exist, but are excluded from DEEP2 catalog.
Rmag_Limit
This parameter is set to '>' if the associated magnitude is
a lower (bright) limit rather than a measured value.
Rmag
The R-band magnitude of the DEEP2 counterpart, for every X-ray
source with a secure DEEP2 counterpart. If optical or IR coverage exists but
no secure counterpart was detected, then an upper limit for the magnitude is
given, whereas X-ray sources with no optical or IR coverage are left blank.
DEEP2_CXO_Offset
The positional offset, in arcseconds, between the DEEP2
optical counterpart and the Chandra X-ray source position.
DEEP2_Likelihood
The likelihood ratio LR for the DEEP2 counterpart to the
Chandra X-ray source. For both the DEEP2 and CFHTLS surveys, the authors
consider counterparts with LR > 0.5 as secure, giving a ~6% contamination rate
in both cases.
DEEP2_ID
The DEEP2 counterpart ID number (see Coil et al. 2004, ApJ, 617,
765).
Imag_Limit
This parameter is set to '>' if the associated magnitude is
a lower (bright) limit rather than a measured value.
Imag
The i-prime (i') band AB magnitude of the CHFTLS counterpart, for
every X-ray source with a secure CFHTLS counterpart. If optical or IR coverage
exists but no secure counterpart was detected, then an upper limit for the
magnitude is given, whereas X-ray sources with no optical or IR coverage are
left blank.
CFHTLS_CXO_Offset
The positional offset, in arcseconds, between the CFHTLS
optical counterpart and the Chandra X-ray source position.
CFHTLS_Likelihood
The likelihood ratio LR for the CFHTLS counterpart to the
Chandra X-ray source. For both the DEEP2 and CFHTLS surveys, the authors
consider counterparts with LR > 0.5 as secure, giving a ~6% contamination rate
in both cases.
CFHTLS_ID
The CFHTLS counterpart ID number (see
http://terapix.iap.fr/article.php?id_article=556).
IRAC_3p6_um_Mag_Limit
This parameter is set to '>' if the associated
magnitude is a lower (bright) limit rather than a measured value.
IRAC_3p6_um_Mag
The 3.6-um magnitude of the Spitzer IRAC counterpart,
for each source with a secure IRAC counterpart. If optical or IR coverage
exists but no secure counterpart was detected, then an upper limit for the
magnitude is given, whereas X-ray sources with no optical or IR coverage are
left blank.
IRAC_CXO_Offset
The positional offset, in arcseconds, between the IRAC
infrared counterpart and the Chandra X-ray source position.
IRAC_Likelihood
The likelihood ratio LR for the IRAC counterpart to the
Chandra X-ray source. A total of 882 Chandra sources are covered by the
Spitzer region. Using the maximum likelihood method, and considering
only matches with LR > 0.5, the authors find that 830 (94.1%) have secure
3.6-um counterparts. This cut on LR gives a ~ 1% spurious counterpart rate.
IRAC_ID
The truncated IRAC object 3.6-micron identification of the
counterpart to the X-ray source, from Barmby et al. (2008, ApJS, 177, 431).
The complete IRAC name of the object should be preceded by a prefix of
'EGSIRAC '.