Search in Xamin or Browse... |
CALCHDMSTR - CALET CHarge Detector (CHD) Master Catalog |
HEASARC Archive |
CALET is a Japanese mission led by JAXA, in collaboration with the Italian Space Agency (ASI) and NASA, and is dedicated to the study of high energy cosmic rays. CALET was launched on August 19, 2015, by a Japanese carrier, H2 Transfer Vehicle, and robotically installed on the Japanese Experiment Module-Exposed Facility (JEM-EF) on the International Space Station (ISS). CALET started scientific observations in October, 2015.
On-orbit operations and offline data processing of CALET onboard the ISS. Asaoka Y. et al., 2018, Astrophysical Particle, 100 29a =2018APh...100...29A
The CALET detector consists of a CHarge Detector (CHD), which identifies the charge of the incident particle in an IMaging Calorimeter (IMC). The IMC reconstructs the track of the incident particle and finely images the initial shower development, and a Total AbSorption Calorimeter (TASC), which absorbs the entire energy of the incoming particle and identifies the particle species using hodoscopic scintillator arrays. The calorimeter directly measures the cosmic ray electron spectrum in the energy range of 1 GeV to 20 TeV.
The CHD is double-layered (X, Y), placed at the top, above the IMC detector. The signals from the X and Y layers are integrated over 1 second and used to create the 1-day lightcurves associated with this database table.
Each row of the database table corresponds to a specific day and has an associated lightcurve. Each record also includes the minimum, maximum, and average of the lightcurve.
ObsID
This parameter contains a unique row identifier for the database table. It is
a 8-digit number, YYYYMMDD, representing the year, month and day of the
lightcurve. It is also used to name the lightcurves.
Time
The start time of the lightcurve. The data have been divided into 1-day
observations. This time corresponds to the start of the day.
End_Time
The end time of the lightcurve. The data have been divided into 1-day
observations. This time corresponds to the end of the day.
Exposure
This parameter corresponds to the total effective exposure recorded
in the 1-day time interval lightcurve.
Processing_Date
This parameter records the date when the data were last processed.
Processing_Version
This records the version of the processing script used in the pipeline to
generate the data products for the observation.
Rate_Mean
Records the mean value of the count rate in the 1-day lightcurve.
Rate_Min
Records the minimum value of the count rate in the 1-day lightcurve.
Rate_Max
Records the maximum value of the count rate in the 1-day lightcurve.