Search in Xamin or Browse... |
CARINAXMM - Carina OB1 Association XMM-Newton X-Ray Point Source Catalog |
HEASARC Archive |
X-ray study of early type stars in the Carina OB1 association Antokhin I.I., Rauw G., Vreux J.-M., van der Hucht K.A., Brown J.C. <Astron. Astrophys. 477, 593 (2008)> =2008A&A...477..593A
Source_Number
A running source number in order of increasing J2000.0
Right Ascension, which uniquely identifies the X-ray source, but not the
entry in the table. Since this table contains all (557) X-ray detections of
235 sources for which the total logarithmic likelihood exceeds 10.0 in 5
separate overlapping XMM-Newton observations of this region, and many sources
were detected in more than one observation, the combination of source
number and data set number (data_set) uniquely specifies an entry in this
table.
Name
The name of the X-ray source using the '[ARV2008]' prefix (where ARV2008
refers to Antokhin, Rauw, Vreux 2008), together with the X-ray source number,
as recommended by the CDS Dictionary of Nomenclature of Celestial Objects.
Var_Status
The set-to-set variability status of the X-ray source,
as follows (see Section 5.2 of the reference paper for more details):
Uncert = Uncertain variability status Const = Non-variable source Var = Variable source Noinfo = Not sufficient data to perform the variability test
Data_Set
The data set number, e.g., 1, or the numbers of the data sets which were
combined, e.g., 3+4+5, in which the X-ray source detection was made. The full
details of the 5 data sets used in this analysis are given in Table 1 of the
reference paper.
PN_Detect_Likelihood
The logarithmic likelihood L2 of the detection of the X-ray source for the
EPIC PN instrument in the specified data set. L2 obeys the simple
relationship L2 = - ln p, where p is the probability for a random
Poissonian fluctuation to have caused the observed source counts.
PN_Rate
The total count rate of the X-ray source in the specified data set in the
whole PN energy band (0.4-10.0 keV), in ct/s.
PN_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
PN_SB_Rate
The count rate of the X-ray source in the specified data set in the soft PN
energy band (0.4-1.0 keV), in ct/s.
PN_SB_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
PN_MB_Rate
The count rate of the X-ray source in the specified data set in the medium PN
energy band (1.0-2.5 keV), in ct/s.
PN_MB_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
PN_HB_Rate
The count rate of the X-ray source in the specified data set in the hard PN
energy band (2.5-10.0 keV), in ct/s.
PN_HB_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
M1_Detect_Likelihood
The logarithmic likelihood L2 of the detection of the X-ray source for the
EPIC MOS1 instrument in the specified data set. L2 obeys the simple
relationship L2 = - ln p, where p is the probability for a random
Poissonian fluctuation to have caused the observed source counts.
M1_Rate
The total count rate of the X-ray source in the specified data set in the
whole MOS1 energy band (0.4-10.0 keV), in ct/s.
M1_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
M1_SB_Rate
The count rate of the X-ray source in the specified data set in the soft MOS1
energy band (0.4-1.0 keV), in ct/s.
M1_SB_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
M1_MB_Rate
The count rate of the X-ray source in the specified data set in the medium
MOS1 energy band (1.0-2.5 keV), in ct/s.
M1_MB_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
M1_HB_Rate
The count rate of the X-ray source in the specified data set in the hard MOS1
energy band (2.5-10.0 keV), in ct/s.
M1_HB_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
M2_Detect_Likelihood
The logarithmic likelihood L2 of the detection of the X-ray source for the
EPIC MOS2 instrument in the specified data set. L2 obeys the simple
relationship L2 = - ln p, where p is the probability for a random
Poissonian fluctuation to have caused the observed source counts.
M2_Rate
The total count rate of the X-ray source in the specified data set in the
whole MOS2 energy band (0.4-10.0 keV), in ct/s.
M2_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
M2_SB_Rate
The count rate of the X-ray source in the specified data set in the soft MOS2
energy band (0.4-1.0 keV), in ct/s.
M2_SB_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
M2_MB_Rate
The count rate of the X-ray source in the specified data set in the medium
MOS2 energy band (1.0-2.5 keV), in ct/s
M2_MB_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
M2_HB_Rate
The count rate of the X-ray source in the specified data set in the hard MOS2
energy band (2.5-10.0 keV), in ct/s.
M2_HB_Rate_Error
The RMS uncertainty in the associated count rate parameter, in ct/s.
Alt_Name
The alternative X-ray source designation using the standard J2000.0
position-based naming convention for serendipitous XMM-Newton sources, e.g.,
'XMMU J104236.8-594357', as registered with the CDS Dictionary of
Nomenclature of Celestial Objects.
RA
The Right Ascension of the X-ray source in the selected equinox. This was
given in J2000.0 coordinates to a precision of 0.01 seconds of time in the
original table. The quoted position is always of the XMM-Newton source, even
if a Chandra counterpart to the source has been detected.
Dec
The Declination of the X-ray source in the selected equinox. This was given
in J2000.0 coordinates to a precision of 0.1 arcseconds in the original
table. The quoted position is always of the XMM-Newton source, even if a
Chandra counterpart to the source has been detected.
LII
The Galactic Longitude of the X-ray source.
BII
The Galactic Latitude of the X-ray source.
AC03_Source_Number
The X-ray source number of the corresponding source in the Albacete-Colombo
et al. (2003, ADS bibcode 2003MNRAS.346..704A) Catalog.
Ev03_Source_Number
The X-ray source number of the corresponding source in the Evans et al.
(2003, CDS Cat. <J/ApJ/589/509>) Catalog.
Num_2MASS_Ctrparts
The number of 2MASS counterparts within 4.0 arcseconds radius of the X-ray
source position.
XMM_2MASS_Offset
The angular separation between the X-ray source and infrared counterpart
positions, in arcseconds.
Jmag
The J band magnitude from the 2MASS Catalog of the infrared counterpart to
the X-ray source.
Hmag
The H band magnitude from the 2MASS Catalog of the infrared counterpart to
the X-ray source.
Ks_Mag
The KS band magnitude from the 2MASS Catalog of the infrared counterpart to
the X-ray source.
Vmag
The V magnitude of the optical counterpart to the X-ray source.
BV_Color
The B-V color of the optical counterpart to the X-ray source.
UB_Color
The U-B color of the optical counterpart to the X-ray source.
Optical_Name
The name of the optical counterpart to the X-ray source. The full Simbad
nomenclature for the optical names used here is:
Tr 16 NNN = Cl* Trumpler 16 NNN in Simbad MJ NNN = Cl* Trumpler 16 MJ NNN in Simbad DETCW-14 NNN = DETWC Tr 14 JHHMMSS.s-DDMMSS in Simbadwhere DETWC refers to Degioia-Eastwood et al. (2001, CDS Cat. <J/ApJ/549/578>).
Spect_Type
The MK spectral type of the optical counterpart to the X-ray source.
Ref_Photometry
This parameter gives the code for the reference from various optical
photometric catalogs, as follows:
Cud = Cudworth et al., 1993, CDS Cat. <J/AJ/105/1822> DETWC = Degioia-Eastwood et al., 2001, CDS Cat. <J/ApJ/549/578> MJ = Massey & Johnson, 1993, CDS Cat. <J/AJ/105/980>
Prob_Membership
The membership probability of the optical counterpart to the X-ray source,
taken from the proper motion study of Cudworth et al. (1993, CDS Cat.
<J/AJ/105/1822>)