Search in Xamin or Browse... |
EFEDSHARD - eROSITA Final Equatorial Depth Survey (eFEDS) Hard X-Ray (2.3-5.0 keV) Source Catalog |
HEASARC Archive |
A multi-stage source detection procedure was optimized and calibrated by performing realistic simulations of the eROSITA eFEDS observations. The authors cross-matched the eROSITA eFEDS source catalog with previous XMM-ATLAS observations, confirming excellent agreement of the eROSITA and XMM-ATLAS source fluxes.
This table presents the hard band sample of 246 sources detected in the energy range 2.3-5.0 keV above a detection likelihood of 10. These sources were detected in three bands (0.2-0.6, 0.6-2.3, and 2.3-5keV) with detect_likelihood >=5 and extent_likelihood = 0 (i.e. point sources). The linked EFEDSMAIN table presents the primary catalog of 27910 X-ray sources, including 542 with significant spatial extent, detected in the 0.2-2.3 keV energy range with detection likelihoods >=6 , corresponding to a (point source) flux limit of ~6.5 x 10-15 erg/cm2/s in the 0.5-2.0 keV energy band (80% completeness). A supplementary catalog contains 4774 low-significance source candidates with detection likelihoods between 5 and 6. The dedicated data analysis software package, calibration database, and calibrated data products are described in an appendix.
Additional information for the eROSITA early data release observations is available at the eROSITA-DE EDR website.
Brunner et al. (2022), "The eROSITA Final Equatorial Depth Survey (eFEDS): The X-ray catalog", <A&A, 661, 1 (2022)> =2022A&A...661A...1B
Name
The eFEDS source designation in the form 'eFEDS JHHMMSS.S+DDMMSS', which uses
the J2000.0 equatorial coordinates truncated to 0.1 arcseconds in RA and to 1
arcsecond in Declination. [NAME]
Source_Number
The unique identification number for each source in this catalog. [ID_SRC]
Main_Source_Number
The matching identification number for corresponding source in the main
catalog, EFEDSMAIN. [ID_main]
RA_Raw
The uncorrected right ascension of the source in the selected equinox. This
was given in J2000 decimal degree coordinates to an accuracy of 10-5
degrees (0.036 arcseconds) in the original reference. [RA]
Dec_Raw
The uncorrected declination of the source in the selected equinox. This was
given in J2000 decimal degree coordinates to an accuracy of 10-6 degrees
(0.0036 arcseconds) in the original reference. [DEC]
Error_Radius_Raw
The uncertainty in the uncorrected position, in arcseconds, based on the
combined uncertainties in the ra and dec coordinates. [RADEC_ERR]
RA
The astrometrically-corrected right ascension of the source in the selected
equinox, based on matches to Gaia un-WISE AGN catalog (Shu et al. 2019). The
computed corrections follow Equation 1 given in the reference paper (see
Section 3.3). These values were given in J2000 decimal degree coordinates to
an accuracy of 10-5 degrees (0.036 arcseconds) in the original reference.
[RA_CORR]
Dec
The astrometrically-corrected declination of the source in the selected
equinox, based on matches to Gaia un-WISE AGN catalog (Shu et al. 2019). The
computed corrections follow Equation 1 given in the reference paper (see
Section 3.3). These values were given in J2000 decimal degree coordinates to
an accuracy of 10-6 degrees (0.0036 arcseconds) in the original reference.
[DEC_CORR]
LII
The astrometrically-corrected Galactic longitude of the source. The HEASARC
has computed this from the astrometrically-corrected right ascension and
declination values.
BII
The astrometrically-corrected Galactic latitude of the source. The HEASARC
has computed this from the astrometrically-corrected right ascension and
declination values.
Error_Radius
The uncertainty in the astrometrically-corrected position, in arcseconds,
based on the combined uncertainties in the astrometrically-corrected right
ascension and declination coordinates. [RADEC_ERR_CORR]
Source_Extent
The extent of the source, given in arcseconds. Values of 0.0 indicate point
sources. [EXT]
Source_Extent_Error
The uncertainty in the extent of the source, given in arcseconds. Values of
0.0 indicate point sources. [EXT_ERR]
Extent_Likelihood
The likelihood associated with the extent measurement. Values of 0.0 indicate
point sources. [EXT_LIKE]
Detect_Likelihood
The detection likelihood based on the combined three-band analysis. This
catalog includes sources that were detected in three bands (0.2-0.6, 0.6-2.3,
and 2.3-5 keV) with detect_likelihood >=5 and with detect_likelihood >= 10 in
the 2.3-5 keV band and extent_likelihood = 0 (i.e. point sources).
[DET_LIKE_0]
Count_Rate
The net count rate for the source, based on PSF-fitting the three-band
(0.2-0.6, 0.6-2.3, and 2.3-5 keV) combined dataset. [ML_RATE_0]
Count_Rate_Error
The 1-sigma uncertainty in the net count rate for the three-band (0.2-0.6,
0.6-2.3, and 2.3-5keV) combined dataset. [ML_RATE_ERR_0]
Counts
The background-subtracted net counts for the source, measured from the
three-band (0.2-0.6, 0.6-2.3, and 2.3-5keV) combined dataset count_rate.
[ML_CTS_0]
Counts_Error
The 1-sigma uncertainty in the net counts for the three-band (0.2-0.6,
0.6-2.3, and 2.3-5keV) combined dataset. [ML_CTS_ERR_0]
Flux
The flux of the source in the three-band (0.2-0.6, 0.6-2.3, and 2.3-5keV)
combined dataset, in units of erg/s/cm2. The energy conversion factor (ECF;
listed in Table D.1 of the reference paper) between the count rates and
fluxes is based on a power-law model with Gamma=2.0 and with Galactic
absorption (NH=3 x 1020 cm-2). [ML_FLUX_0]
Flux_Error
The 1-sigma uncertainty in the three-band (0.2-0.6, 0.6-2.3, and 2.3-5 keV)
combined dataset flux, in units of erg/s/cm2. [ML_FLUX_ERR_0]
Bkg_Counts
The background counts, in units of counts/arcmin2, at the source position
in the three-band (0.2-0.6, 0.6-2.3, and 2.3-5keV) combined dataset.
[ML_BKG_0]
Inarea90_Flag
A flag (with possible values 'T' or 'F') designating sources within the
inner region of the eFEDS field, where the exposure times exceed 500s and
which comprises 90% of the eFEDS field area. [inArea90]
Tb1_Detect_Likelihood
The detection likelihood based on forced PSF-fitting in the 0.2-0.6 keV band.
[DET_LIKE_1]
Tb2_Detect_Likelihood
The detection likelihood based on forced PSF-fitting in the 0.6-2.3 keV band.
[DET_LIKE_2]
Tb3_Detect_Likelihood
The detection likelihood based on forced PSF-fitting in the 2.3-5 keV band.
[DET_LIKE_3]
Tb1_Count_Rate
The net count rate for the source in the 0.2-0.6 keV band, based on forced
PSF-fitting, as described in Section 3.4 of the reference paper. [ML_RATE_1]
Tb2_Count_Rate
The net count rate for the source in the 0.6-2.3 keV band, based on forced
PSF-fitting, as described in Section 3.4 of the reference paper. [ML_RATE_2]
Tb3_Count_Rate
The net count rate for the source in the 2.3-5 keV band, based on forced
PSF-fitting, as described in Section 3.4 of the reference paper. [ML_RATE_3]
Tb1_Count_Rate_Error
The 1-sigma uncertainty in the 0.2-0.6 keV net count rate. [ML_RATE_ERR_1]
Tb2_Count_Rate_Error
The 1-sigma uncertainty in the 0.6-2.3 keV net count rate. [ML_RATE_ERR_2]
Tb3_Count_Rate_Error
The 1-sigma uncertainty in the 2.3-5 keV net count rate. [ML_RATE_ERR_3]
Tb1_Counts
The background-subtracted 0.2-0.6 keV net counts for the source, measured
from the forced PSF-fitted count rate, e.g., b2_count_rate. [ML_CTS_1]
Tb2_Counts
The background-subtracted 0.6-2.3 keV net counts for the source, measured
from the forced PSF-fitted count rate, e.g., b2_count_rate. [ML_CTS_2]
Tb3_Counts
The background-subtracted 2.3-5 keV net counts for the source, measured from
the forced PSF-fitted count rate, e.g., b2_count_rate. [ML_CTS_3]
Tb1_Counts_Error
The 1-sigma uncertainty in the 0.2-0.6 keV net counts. [ML_CTS_ERR_1]
Tb2_Counts_Error
The 1-sigma uncertainty in the 0.6-2.3 keV net counts. [ML_CTS_ERR_2]
Tb3_Counts_Error
The 1-sigma uncertainty in the 2.3-5 keV net counts. [ML_CTS_ERR_3]
Tb1_Flux
The flux of the source in the 0.2-0.6 keV band, in units of erg/s/cm2,
measured from the forced PSF-fitted count rate, e.g., b1_count_rate. The
energy conversion factor (ECF; listed in Table D.1 of the reference paper)
between the count rates and fluxes is based on a power-law model with
Gamma=2.0 and with Galactic absorption (NH=3 x 1020 cm-2). [ML_FLUX_1]
Tb2_Flux
The flux of the source in the 0.6-2.3 keV band, in units of erg/s/cm2,
measured from the forced PSF-fitted count rate, e.g., b1_count_rate. The
energy conversion factor (ECF; listed in Table D.1 of the reference paper)
between the count rates and fluxes is based on a power-law model with
Gamma=2.0 and with Galactic absorption (NH=3 x 1020 cm-2). [ML_FLUX_2]
Tb3_Flux
The flux of the source in the 2.3-5 keV band, in units of erg/s/cm2,
measured from the forced PSF-fitted count rate, e.g., b1_count_rate. The
energy conversion factor (ECF; listed in Table D.1 of the reference paper)
between the count rates and fluxes is based on a power-law model with
Gamma=2.0 and with Galactic absorption (NH=3 x 1020 cm-2). [ML_FLUX_3]
Tb1_Flux_Error
The 1-sigma uncertainty in the 0.2-0.6 keV flux, in units of erg/s/cm2.
[ML_FLUX_ERR_1]
Tb2_Flux_Error
The 1-sigma uncertainty in the 0.6-2.3 keV flux, in units of erg/s/cm2.
[ML_FLUX_ERR_2]
Tb3_Flux_Error
The 1-sigma uncertainty in the 2.3-5 keV flux, in units of erg/s/cm2.
[ML_FLUX_ERR_3]
Tb1_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
0.2-0.6 keV band. [ML_EXP_1]
Tb2_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
0.6-2.3 keV band. [ML_EXP_2]
Tb3_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
2.3-5 keV band. [ML_EXP_3]
Tb1_Bkg_Counts
The background counts, in units of counts/arcmin2, at the source position
in the 0.2-0.6 keV band. [ML_BKG_1]
Tb2_Bkg_Counts
The background counts, in units of counts/arcmin2, at the source position
in the 0.6-2.3 keV band. [ML_BKG_2]
Tb3_Bkg_Counts
The background counts, in units of counts/arcmin2, at the source position
in the 2.3-5 keV band. [ML_BKG_3]
B1_Detect_Likelihood
The detection likelihood based on forced PSF-fitting in the 0.2-0.5 keV band.
[DET_LIKE_b1]
B2_Detect_Likelihood
The detection likelihood based on forced PSF-fitting in the 0.5-1 keV band.
[DET_LIKE_b2]
B3_Detect_Likelihood
The detection likelihood based on forced PSF-fitting in the 1-2 keV band.
[DET_LIKE_b3]
B4_Detect_Likelihood
The detection likelihood based on forced PSF-fitting in the 2-4.5 keV band.
[DET_LIKE_b4]
SB_Detect_Likelihood
The detection likelihood based on forced PSF-fitting in the 0.5-2.0 keV band.
[DET_LIKE_s]
HB_Detect_Likelihood
The detection likelihood based on forced PSF-fitting in the 1.2-5 keV band.
[DET_LIKE_h]
UB_Detect_Likelihood
The detection likelihood based on forced PSF-fitting in the 5-8 keV band.
[DET_LIKE_u]
B1_Count_Rate
The net count rate for the source in the 0.2-0.5 keV band, based on forced
PSF-fitting, as described in Section 3.4 of the reference paper. [ML_RATE_b1]
B2_Count_Rate
The net count rate for the source in the 0.5-1 keV band, based on forced
PSF-fitting, as described in Section 3.4 of the reference paper. [ML_RATE_b2]
B3_Count_Rate
The net count rate for the source in the 1-2 keV band, based on forced
PSF-fitting, as described in Section 3.4 of the reference paper. [ML_RATE_b3]
B4_Count_Rate
The net count rate for the source in the 2-4.5 keV band, based on forced
PSF-fitting, as described in Section 3.4 of the reference paper. [ML_RATE_b4]
SB_Count_Rate
The net count rate for the source in the 0.5-2 keV band, based on forced
PSF-fitting, as described in Section 3.4 of the reference paper. [ML_RATE_s]
HB_Count_Rate
The net count rate for the source in the 2.3-5 keV band, based on forced
PSF-fitting, as described in Section 3.4 of the reference paper. [ML_RATE_h]
UB_Count_Rate
The net count rate for the source in the 5-8 keV band, based on forced
PSF-fitting, as described in Section 3.4 of the reference paper. [ML_RATE_u]
B1_Count_Rate_Error
The 1-sigma uncertainty in the 0.2-0.5 keV net count rate. [ML_RATE_ERR_b1]
B2_Count_Rate_Error
The 1-sigma uncertainty in the 0.5-1 keV net count rate. [ML_RATE_ERR_b2]
B3_Count_Rate_Error
The 1-sigma uncertainty in the 1-2 keV net count rate. [ML_RATE_ERR_b3]
B4_Count_Rate_Error
The 1-sigma uncertainty in the 2-4.5 keV net count rate. [ML_RATE_ERR_b4]
SB_Count_Rate_Error
The 1-sigma uncertainty in the 0.5-2 keV net count rate. [ML_RATE_ERR_s]
HB_Count_Rate_Error
The 1-sigma uncertainty in the 2.3-5 keV net count rate. [ML_RATE_ERR_h]
UB_Count_Rate_Error
The 1-sigma uncertainty in the 5-8 keV net count rate. [ML_RATE_ERR_u]
B1_Count_Rate_Lower
The 1-sigma lower error value in the 0.2-0.5 keV net count rate.
[ML_RATE_LOWERR_b1]
B2_Count_Rate_Lower
The 1-sigma lower error value in the 0.5-1 keV net count rate.
[ML_RATE_LOWERR_b2]
B3_Count_Rate_Lower
The 1-sigma lower error value in the 1-2 keV net count rate.
[ML_RATE_LOWERR_b3]
B4_Count_Rate_Lower
The 1-sigma lower error value in the 2-4.5 keV net count rate.
[ML_RATE_LOWERR_b4]
SB_Count_Rate_Lower
The 1-sigma lower error value in the 0.5-2 keV net count rate.
[ML_RATE_LOWERR_s]
HB_Count_Rate_Lower
The 1-sigma lower error value in the 2.3-5 keV net count rate.
[ML_RATE_LOWERR_h]
UB_Count_Rate_Lower
The 1-sigma lower error value in the 5-8 keV net count rate.
[ML_RATE_LOWERR_u]
B1_Count_Rate_Upper
The 1-sigma upper error value in the 0.2-0.5 keV net count rate.
[ML_RATE_UPERR_b1]
B2_Count_Rate_Upper
The 1-sigma upper error value in the 0.5-1 keV net count rate.
[ML_RATE_UPERR_b2]
B3_Count_Rate_Upper
The 1-sigma upper error value in the 1-2 keV net count rate.
[ML_RATE_UPERR_b3]
B4_Count_Rate_Upper
The 1-sigma upper error value in the 2-4.5 keV net count rate.
[ML_RATE_UPERR_b4]
SB_Count_Rate_Upper
The 1-sigma upper error value in the 0.5-2 keV net count rate.
[ML_RATE_UPERR_s]
HB_Count_Rate_Upper
The 1-sigma upper error value in the 2.3-5 keV net count rate.
[ML_RATE_UPERR_h]
UB_Count_Rate_Upper
The 1-sigma upper error value in the 5-8 keV net count rate.
[ML_RATE_UPERR_u]
B1_Counts
The background-subtracted 0.2-0.5 keV net counts for the source, measured
from the forced PSF-fitted count rate, e.g., b1_count_rate. [ML_CTS_b1]
B2_Counts
The background-subtracted 0.5-1 keV net counts for the source, measured from
the forced PSF-fitted count rate, e.g., b2_count_rate. [ML_CTS_b2]
B3_Counts
The background-subtracted 1-2 keV net counts for the source, measured from
the forced PSF-fitted count rate, e.g., b3_count_rate. [ML_CTS_b3]
B4_Counts
The background-subtracted 2-4.5 keV net counts for the source, measured from
the forced PSF-fitted count rate, e.g., b4_count_rate. [ML_CTS_b4]
SB_Counts
The background-subtracted 0.5-2 keV net counts for the source, measured from
the forced PSF-fitted count rate, e.g., sb_count_rate. [ML_CTS_s]
HB_Counts
The background-subtracted 2.3-5 keV net counts for the source, measured from
the forced PSF-fitted count rate, e.g., hb_count_rate. [ML_CTS_h]
UB_Counts
The background-subtracted 5-8 keV net counts for the source, measured from
the forced PSF-fitted count rate, e.g., ub_count_rate. [ML_CTS_u]
B1_Counts_Error
The 1-sigma uncertainty in the 0.2-0.5 keV net counts. [ML_CTS_ERR_b1]
B2_Counts_Error
The 1-sigma uncertainty in the 0.5-1 keV net counts. [ML_CTS_ERR_b2]
B3_Counts_Error
The 1-sigma uncertainty in the 1-2 keV net counts. [ML_CTS_ERR_b3]
B4_Counts_Error
The 1-sigma uncertainty in the 2-4.5 keV net counts. [ML_CTS_ERR_b4]
SB_Counts_Error
The 1-sigma uncertainty in the 0.5-2 keV net counts. [ML_CTS_ERR_s]
HB_Counts_Error
The 1-sigma uncertainty in the 2.3-5 keV net counts. [ML_CTS_ERR_h]
UB_Counts_Error
The 1-sigma uncertainty in the 5-8 keV net counts. [ML_CTS_ERR_u]
B1_Counts_Lower
The 1-sigma lower error in the 0.2-0.5 keV net counts. [ML_CTS_LOWERR_b1]
B2_Counts_Lower
The 1-sigma lower error in the 0.5-1 keV net counts. [ML_CTS_LOWERR_b2]
B3_Counts_Lower
The 1-sigma lower error in the 1-2 keV net counts. [ML_CTS_LOWERR_b3]
B4_Counts_Lower
The 1-sigma lower error in the 2-4.5 keV net counts. [ML_CTS_LOWERR_b4]
SB_Counts_Lower
The 1-sigma lower error in the 0.5-2 keV net counts. [ML_CTS_LOWERR_s]
HB_Counts_Lower
The 1-sigma lower error in the 2.3-5 keV net counts. [ML_CTS_LOWERR_h]
UB_Counts_Lower
The 1-sigma lower error in the 5-8 keV net counts. [ML_CTS_LOWERR_u]
B1_Counts_Upper
The 1-sigma upper error in the 0.2-0.5 keV net counts. [ML_CTS_UPERR_b1]
B2_Counts_Upper
The 1-sigma upper error in the 0.5-1 keV net counts. [ML_CTS_UPERR_b2]
B3_Counts_Upper
The 1-sigma upper error in the 1-2 keV net counts. [ML_CTS_UPERR_b3]
B4_Counts_Upper
The 1-sigma upper error in the 2-4.5 keV net counts. [ML_CTS_UPERR_b4]
SB_Counts_Upper
The 1-sigma upper error in the 0.5-2 keV net counts. [ML_CTS_UPERR_s]
HB_Counts_Upper
The 1-sigma upper error in the 2.3-5 keV net counts. [ML_CTS_UPERR_h]
UB_Counts_Upper
The 1-sigma upper error in the 5-8 keV net counts. [ML_CTS_UPERR_u]
B1_Flux
The flux of the source in the 0.2-0.5 keV band, in units of erg/s/cm2,
measured from the forced PSF-fitted count rate, e.g., b1_count_rate. The
energy conversion factor (ECF; listed in Table D.1 of the reference paper)
between the count rates and fluxes is based on a power-law model with
Gamma=2.0 and with Galactic absorption (NH=3 x 1020 cm-2). [ML_FLUX_b1]
B2_Flux
The flux of the source in the 0.5-1 keV band, in units of erg/s/cm2,
measured from the forced PSF-fitted count rate, e.g., b1_count_rate. The
energy conversion factor (ECF; listed in Table D.1 of the reference paper)
between the count rates and fluxes is based on a power-law model with
Gamma=2.0 and with Galactic absorption (NH=3 x 1020 cm-2). [ML_FLUX_b2]
B3_Flux
The flux of the source in the 1-2 keV band, in units of erg/s/cm2, measured
from the forced PSF-fitted count rate, e.g., b1_count_rate. The energy
conversion factor (ECF; listed in Table D.1 of the reference paper) between
the count rates and fluxes is based on a power-law model with Gamma=2.0 and
with Galactic absorption (NH=3 x 1020 cm-2). [ML_FLUX_b3]
B4_Flux
The flux of the source in the 2-4.5 keV band, in units of erg/s/cm2,
measured from the forced PSF-fitted count rate, e.g., b1_count_rate. The
energy conversion factor (ECF; listed in Table D.1 of the reference paper)
between the count rates and fluxes is based on a power-law model with
Gamma=2.0 and with Galactic absorption (NH=3 x 1020 cm-2). [ML_FLUX_b4]
SB_Flux
The flux of the source in the 0.5-2 keV band, in units of erg/s/cm2,
measured from the forced PSF-fitted count rate, e.g., b1_count_rate. The
energy conversion factor (ECF; listed in Table D.1 of the reference paper)
between the count rates and fluxes is based on a power-law model with
Gamma=2.0 and with Galactic absorption (NH=3 x 1020 cm-2). [ML_FLUX_s]
HB_Flux
The flux of the source in the 2.3-5 keV band, in units of erg/s/cm2,
measured from the forced PSF-fitted count rate, e.g., b1_count_rate. The
energy conversion factor (ECF; listed in Table D.1 of the reference paper)
between the count rates and fluxes is based on a power-law model with
Gamma=2.0 and with Galactic absorption (NH=3 x 1020 cm-2). [ML_FLUX_h]
UB_Flux
The flux of the source in the 5-8 keV band, in units of erg/s/cm2, measured
from the forced PSF-fitted count rate, e.g., b1_count_rate. The energy
conversion factor (ECF; listed in Table D.1 of the reference paper) between
the count rates and fluxes is based on a power-law model with Gamma=2.0 and
with Galactic absorption (NH=3 x 1020 cm-2). [ML_FLUX_u]
B1_Flux_Error
The 1-sigma uncertainty in the 0.2-0.5 keV flux, in units of erg/s/cm2.
[ML_FLUX_ERR_b1]
B2_Flux_Error
The 1-sigma uncertainty in the 0.5-1 keV flux, in units of erg/s/cm2.
[ML_FLUX_ERR_b2]
B3_Flux_Error
The 1-sigma uncertainty in the 1-2 keV flux, in units of erg/s/cm2.
[ML_FLUX_ERR_b3]
B4_Flux_Error
The 1-sigma uncertainty in the 2-4.5 keV flux, in units of erg/s/cm2.
[ML_FLUX_ERR_b4]
SB_Flux_Error
The 1-sigma uncertainty in the 0.5-2 keV flux, in units of erg/s/cm2.
[ML_FLUX_ERR_s]
HB_Flux_Error
The 1-sigma uncertainty in the 2.3-5 keV flux, in units of erg/s/cm2.
[ML_FLUX_ERR_h]
UB_Flux_Error
The 1-sigma uncertainty in the 5-8 keV flux, in units of erg/s/cm2.
[ML_FLUX_ERR_u]
B1_Flux_Lower
The 1-sigma lower error value in the 0.2-0.5 keV flux, in units of
erg/s/cm2. [ML_FLUX_LOWERR_b1]
B2_Flux_Lower
The 1-sigma lower error value in the 0.5-1 keV flux, in units of erg/s/cm2.
[ML_FLUX_LOWERR_b2]
B3_Flux_Lower
The 1-sigma lower error value in the 1-2 keV flux, in units of erg/s/cm2.
[ML_FLUX_LOWERR_b3]
B4_Flux_Lower
The 1-sigma lower error value in the 2-4.5 keV flux, in units of erg/s/cm2.
[ML_FLUX_LOWERR_b4]
SB_Flux_Lower
The 1-sigma lower error value in the 0.5-2 keV flux, in units of erg/s/cm2.
[ML_FLUX_LOWERR_s]
HB_Flux_Lower
The 1-sigma lower error value in the 2.3-5 keV flux, in units of erg/s/cm2.
[ML_FLUX_LOWERR_h]
UB_Flux_Lower
The 1-sigma lower error value in the 5-8 keV flux, in units of erg/s/cm2.
[ML_FLUX_LOWERR_u]
B1_Flux_Upper
The 1-sigma upper error value in the 0.2-5 keV flux, in units of erg/s/cm2.
[ML_FLUX_UPERR_b1]
B2_Flux_Upper
The 1-sigma upper error value in the 0.5-1 keV flux, in units of erg/s/cm2.
[ML_FLUX_UPERR_b2]
B3_Flux_Upper
The 1-sigma upper error value in the 1-2 keV flux, in units of erg/s/cm2.
[ML_FLUX_UPERR_b3]
B4_Flux_Upper
The 1-sigma upper error value in the 2-4.5 keV flux, in units of erg/s/cm2.
[ML_FLUX_UPERR_b4]
SB_Flux_Upper
The 1-sigma upper error value in the 0.5-2 keV flux, in units of erg/s/cm2.
[ML_FLUX_UPERR_s]
HB_Flux_Upper
The 1-sigma upper error value in the 2.3-5 keV flux, in units of erg/s/cm2.
[ML_FLUX_UPERR_h]
UB_Flux_Upper
The 1-sigma upper error value in the 5-8 keV flux, in units of erg/s/cm2.
[ML_FLUX_UPERR_u]
B1_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
0.2-0.5 keV band. [ML_EXP_b1]
B2_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
0.5-1 keV band. [ML_EXP_b2]
B3_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
1-2 keV band. [ML_EXP_b3]
B4_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
2-4.5 keV band. [ML_EXP_b4]
SB_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
0.5-2 keV band. [ML_EXP_s]
HB_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
2.3-5 keV band. [ML_EXP_h]
UB_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
5-8 keV band. [ML_EXP_u]
B1_Bkg_Counts
The background counts, in units of counts/arcmin2, at the source position
in the 0.2-0.5 keV band. [ML_BKG_b1]
B2_Bkg_Counts
The background counts, in units of counts/arcmin2, at the source position
in the 0.5-1 keV band. [ML_BKG_b2]
B3_Bkg_Counts
The background counts, in units of counts/arcmin2, at the source position
in the 1-2 keV band. [ML_BKG_b3]
B4_Bkg_Counts
The background counts, in units of counts/arcmin2, at the source position
in the 2-4.5 keV band. [ML_BKG_b4]
SB_Bkg_Counts
The background counts, in units of counts/arcmin2, at the source position
in the 0.5-2 keV band. [ML_BKG_s]
HB_Bkg_Counts
The background counts, in units of counts/arcmin2, at the source position
in the 2.3-5 keV band. [ML_BKG_h]
UB_Bkg_Counts
The background counts, in units of counts/arcmin2, at the source position
in the 5-8 keV band. [ML_BKG_u]
B1_Aperture_Counts
The background-subtracted 0.2-0.5 keV net counts for the source, measured
from the aperture photometry methods described in Section 4.2 of the
reference paper. [APE_CTS_b1]
B2_Aperture_Counts
The background-subtracted 0.5-1 keV net counts for the source, measured from
the aperture photometry methods described in Section 4.2 of the reference
paper. [APE_CTS_b2]
B3_Aperture_Counts
The background-subtracted 1-2 keV net counts for the source, measured from
the aperture photometry methods described in Section 4.2 of the reference
paper. [APE_CTS_b3]
B4_Aperture_Counts
The background-subtracted 2-4.5 keV net counts for the source, measured from
the aperture photometry methods described in Section 4.2 of the reference
paper. [APE_CTS_b4]
SB_Aperture_Counts
The background-subtracted 0.5-2 keV net counts for the source, measured from
the aperture photometry methods described in Section 4.2 of the reference
paper. [APE_CTS_s]
HB_Aperture_Counts
The background-subtracted 2.3-5 keV net counts for the source, measured from
the aperture photometry methods described in Section 4.2 of the reference
paper. [APE_CTS_h]
UB_Aperture_Counts
The background-subtracted 5-8 keV net counts for the source, measured from
the aperture photometry methods described in Section 4.2 of the reference
paper. [APE_CTS_u]
B1_Aperture_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
0.2-0.5 keV band. [APE_EXP_b1]
B2_Aperture_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
0.5-1 keV band. [APE_EXP_b2]
B3_Aperture_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
1-2 keV band. [APE_EXP_b3]
B4_Aperture_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
2-4.5 keV band. [APE_EXP_b4]
SB_Aperture_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
0.5-2 keV band. [APE_EXP_s]
HB_Aperture_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
2.3-5 keV band. [APE_EXP_h]
UB_Aperture_Exposure
The vignetting-corrected exposure, in seconds, at the source position for the
5-8 keV band. [APE_EXP_u]
B1_Aperture_Bkg_Counts
The background counts in the 0.2-0.5 keV, in units of counts/arcmin2,
within the aperture and excluding nearby sources. [APE_BKG_b1]
B2_Aperture_Bkg_Counts
The background counts in the 0.5-1 keV, in units of counts/arcmin2, within
the aperture and excluding nearby sources. [APE_BKG_b2]
B3_Aperture_Bkg_Counts
The background counts in the 1-2 keV, in units of counts/arcmin2, within
the aperture and excluding nearby sources. [APE_BKG_b3]
B4_Aperture_Bkg_Counts
The background counts in the 2-4.5 keV, in units of counts/arcmin2, within
the aperture and excluding nearby sources. [APE_BKG_b4]
SB_Aperture_Bkg_Counts
The background counts in the 0.5-2 keV, in units of counts/arcmin2, within
the aperture and excluding nearby sources. [APE_BKG_s]
HB_Aperture_Bkg_Counts
The background counts in the 2.3-5 keV, in units of counts/arcmin2, within
the aperture and excluding nearby sources. [APE_BKG_h]
UB_Aperture_Bkg_Counts
The background counts in the 5-8 keV, in units of counts/arcmin2, within
the aperture and excluding nearby sources. [APE_BKG_u]
B1_Aperture_Radius
The aperture radius, in pixels, for the 0.2-0.5 keV band. [APE_RADIUS_b1]
B2_Aperture_Radius
The aperture radius, in pixels, for the 0.5-1 keV band. [APE_RADIUS_b2]
B3_Aperture_Radius
The aperture radius, in pixels, for the 1-2 keV band. [APE_RADIUS_b3]
B4_Aperture_Radius
The aperture radius, in pixels, for the 2-4.5 keV band. [APE_RADIUS_b4]
SB_Aperture_Radius
The aperture radius, in pixels, for the 0.5-2 keV band. [APE_RADIUS_s]
HB_Aperture_Radius
The aperture radius, in pixels, for the 2.3-5 keV band. [APE_RADIUS_h]
UB_Aperture_Radius
The aperture radius, in pixels, for the 5-8 keV band. [APE_RADIUS_u]
B1_Aperture_Prob
The Poisson probability that the source is generated by background
fluctuations, based on the 0.2-0.5 keV band. [APE_POIS_b1]
B2_Aperture_Prob
The Poisson probability that the source is generated by background
fluctuations, based on the 0.5-1 keV band. [APE_POIS_b2]
B3_Aperture_Prob
The Poisson probability that the source is generated by background
fluctuations, based on the 1-2 keV band. [APE_POIS_b3]
B4_Aperture_Prob
The Poisson probability that the source is generated by background
fluctuations, based on the 2-4.5 keV band. [APE_POIS_b4]
SB_Aperture_Prob
The Poisson probability that the source is generated by background
fluctuations, based on the 0.5-2 keV band. [APE_POIS_s]
HB_Aperture_Prob
The Poisson probability that the source is generated by background
fluctuations, based on the 2.3-5 keV band. [APE_POIS_h]
UB_Aperture_Prob
The Poisson probability that the source is generated by background
fluctuations, based on the 5-8 keV band. [APE_POIS_u]