A Quick Example of using PIMMS for ROSAT HRI count rate estimations
pimms
*** PIMMS Version 1.2 (1993 May 26 release) *** Reading mission directory, please wait * PIMMS simulation product is COUNT count rates for various instruments or intrinsic fluxes can be estimated Use 'PRODUCT' to simulate images * Current model is BREMSSTRAHLUNG, kT= 10.0000 keV; NH = 1.000E+21 Use 'MODEL' command to change * By default, input rate is taken to be Flux ( 2.000- 10.000 keV) in ergs/cm/cm/s Use 'FROM' command to change the default * Simulation product will be Count rate in ASCA SIS Use 'INSTRUMENT' command to switch to another instrument
PIMMS > instrument rosat hri
PIMMS > model
PIMMS knows about the following Blackbody (BB) Powerlaw (PL) (Thermal) Bremsstrahlung (TB) RaymondSmith (RS) For the above, enter name, temperature/slope and Nh e.g., model bb 2.4 2e21 PIMMS also knows about following precalculated models: Name Short explanation RSQ60 Raymond-Smith, logT=6.0 (kT=0.086 keV), abundance 0.25 Solar RSQ62 Raymond-Smith, logT=6.2 (kT=0.137 keV), abundance 0.25 Solar [Many others follow] For these, type MODEL[ ] PIMMS can also use any Ascii files containing: energy (kev), flux (photons/cm/cm/s) pairs as model For this, type [ ]
Enter model name > PL
Enter photon index > 2
Enter Nh > 3E20
PIMMS > go 2E-11
* For power law model with photon index = 2.0000; NH = 3.000E+20 and a flux ( 2.000- 10.000keV) of 2.000E-11 ergs/cm/cm/s (Model normalization = 7.779E-03) * PIMMS predicts 6.618E-01 cps with ROSAT HRI
[or, to estimate rosat counts based on another mission]
PIMMS > from einstein hri
PIMMS > go 1
* For power law model with photon index = 2.0000; NH = 3.000E+20 and 1.000E+00 cps in EINSTEIN HRI (Model normalization = 2.282E-02) * PIMMS predicts 1.941E+00 cps with ROSAT HRI
[or change the assumed input flux energy range]
PIMMS > from flux erg 0.1-2
PIMMS > go 1e-11
* For power law model with photon index = 2.0000; NH = 3.000E+20 and a flux ( 0.100- 2.000keV) of 1.000E-11 ergs/cm/cm/s (Model normalization = 3.708E-03) * PIMMS predicts 3.155E-01 cps with ROSAT HRILast Update: Feb 14, 1995 Curator:
HEASARC Guest Observer Facility
Please use the Feedback link if you have questions on ROSAT.