FITSIO Home
Next: Advanced Interface Subroutines
Up: Basic Interface Routines
Previous: Keyword I/O Routines
The following routines read or write data values in the current HDU of
the FITS file. Automatic datatype conversion
will be attempted for numerical datatypes if the specified datatype is
different from the actual datatype of the FITS array or table column.
- 1
- Write elements into the primary data array or image extension.
FTPPR[BIJED](unit,group,fpixel,nelements,values, > status)
- 2
- Read elements from the primary data array or image extension.
Undefined array elements will be
returned with a value = nullval, unless nullval = 0 in which case no
checks for undefined pixels will be performed. The anyf parameter is
set to true (= .true.) if any of the returned
elements were undefined.
FTGPV[BIJED](unit,group,fpixel,nelements,nullval, > values,anyf,status)
- 3
- Write elements into an ASCII or binary table column. The `felem'
parameter applies only to vector columns in binary tables and is
ignored when writing to ASCII tables.
FTPCL[SLBIJEDCM](unit,colnum,frow,felem,nelements,values, > status)
- 4
- Read elements from an ASCII or binary table column. Undefined
array elements will be returned with a value = nullval, unless nullval = 0
(or = ' ' for ftgcvs) in which case no checking for undefined values will
be performed. The ANYF parameter is set to true if any of the returned
elements are undefined.
FTGCV[SBIJEDCM](unit,colnum,frow,felem,nelements,nullval, >
values,anyf,status)
- 5
- Get the table column number and full name of the column whose name
matches the input template string. See the `Advanced Interface Routines'
chapter for a full description of this routine.
FTGCNN(unit,casesen,coltemplate, > colname,colnum,status)