NAME
hxisgdshield - Extract light curves or spectra from shield data for Hitomi HXI or SGD
USAGE
hxisgdshield infile outfile_root outfile_type datatype columnname hkfile hkext
DESCRIPTION
The hxisgdshield Perl script extracts either light curves or spectra from the shield data
of HXI or SGD.
There are three modes for the output data type: light curve (LC), spectra (SPEC),
and "scan" light curve (SCAN). The mode is selected by the parameter 'outfile_type'.
In LC mode ('outfile_type=LC'), the task generates light curves summed over a given energy range,
which is set by the parameter 'energybin'.
The parameter 'energybin' may also be set to ALL
to create light curves summed over all energy bins. The total number of energy bins
varies according to the input data type. Light curves may be generated
from any type of HXI or SGD shield data (see below for a description of the
different data types).
In SPEC mode ('outfile_type=SPEC'), spectra are generated by summing the counts within a
specified time range for each energy channel. Spectra may only be generated from
histogram and gamma-ray burst data (see below for more information
about these data types). The lower and upper bounds of the time range are set
by the hidden parameters 'tstart' and 'tstop', respectively. The parameter 'tstart'
may be set to TSTART, in which case the TSTART keyword of the input extension is
used as the lower time bound. Similarly, the parameter 'tstop' may be set to
TSTOP, in which case the TSTOP keyword of the input extension is used as the
upper time bound. Count-type spectra are always created using the same channel
definitions as the input file type. In addition, if 'deconvolve=yes',
rate-type deconvolved spectra are also produced
with the native instrumental channel definitions (0-4095). In this case,
the counts in each channel from the input data are spread uniformly over
some number of deconvolved channels, and divided by the exposure to compute the rate.
In SCAN mode ('outfile_type=SCAN'), light curves are generated
from the shield data taken during the lower discriminator
scan test. This mode may only be used for scalar data type (see below). The parameters
'tstart' and 'tstop' in SCAN mode have the same meaning and behavior as in SPEC mode.
A housekeeping (HK) file is required for SCAN mode. Times from the TIME column in the
HK file are used to create a good time interval (GTI) file. This GTI file is used to
filter the light curves produced in SCAN mode, and the GTI extension is appended to
the final output file. Each GTI in the file is based on a time from the
HK file. The GTI START column is determined by subtracting the parameter 'gticut_pre'
from each time in the HK file. Similarly, the GTI STOP column is determined by adding
the parameter 'gticut_post' to the time in the HK file.
Input Data Types
Both HXI and SGD input shield FITS data come in three types: scalar (SCL) with
one value in each input column, histogram (HIST) with 128 channels (numbered 0 to 127),
and gamma-ray burst (GRB) data with 32 channels (numbered from 0 to 31). The different types of data are stored in different
files and/or extensions. This task analyzes one type of data at a time, thus users
must choose the type to analyze using the parameter 'datatype'. Once the user chooses
the data type, this task automatically looks for the input data columns in the
appropriate extension(s) of the input data file.
FITS input data for all
three data types contain multiple columns. This task creates one output light curve
or spectrum FITS file for each input column, unless the user specifies particular
column(s) for processing using the parameter 'columnname'.
PARAMETERS
- infile = sclhist.evt [filename]
- Name of input shield FITS data file.
- outfile_root = scl_ [string]
- Initial part of output file name. The name of each column from the input
file is appended to this root to create the base name for the output file. The
suffix ".lc" is used for output light curves and ".pha" for output spectra. For
example, if the 'outfile_root=my_data', the output light curve file produced
from the input column SH1_FBGO1 would be named my_data_SH1_FBGO1.lc.
- outfile_type = LC [string LC|SPEC|SCAN]
- Type of output file.
- datatype = SCL [string SCL|HIST|GRB]
- Data type for which the light curve or spectrum is calculated.
SCL is invalid for SPEC mode. Only 'datatyp=SCL' is available for SCAN mode.
- columnname = all [string]
-
Name of column for which a light curve or spectrum is calculated.
The value may be all, or the user may specify one or more column names, with
multiple column names separated by whitespace or commas. If 'columnname'
is set to all, this task performs the specified calculations
for each input column in the input extension. A separate output FITS file
is produced for each input column selected. For example, if 'columnname'
were set to SH_GRB1 for an HXI GRB light curve, one
output file would be produced. If 'columnname=SH_GRB1, SH_GRB2',
two output files would be produced, and if 'columnname=all', six
output files would be produced for SH_GRB1 through SH_GRB6.
- (energybin = all) [string]
-
Input energy bins for HIST or GRB light curves, expressed either as a range
of channels (e.g., 'energybin=3-10') or all. This parameter is only
used in LC mode. The parameter 'energybin' must be all or 1 for SCL data.
HIST and GRB data have 128 channels and 32 channels, respectively.
Note that the channel number starts from 0, so the last channel of
HIST data is 127, not 128. To select a single bin, users must still
enter a range (e.g., 'energybin=3-3') to include only bin 3. To include
just the first ten channels, users should specify 'energybin=0-9'.
When 'energybin=all', all the channels are used, that is, 0-127
for HIST data and 0-31 for GRB data.
- (tstart = TSTART) [string]
- Start time [s] for generating spectra or SCAN light curves.
Set to TSTART to use the input extension's TSTART keyword. Used only
in SPEC or SCAN mode.
- (tstop = TSTOP) [string]
- Stop time [s] for generating spectra or SCAN light curves.
Set to TSTOP to use the input extension's TSTOP keyword. Used only
in SPEC or SCAN mode.
- (deconvolve = yes) [boolean yes|no]
- If 'deconvolve=yes', deconvolved spectra with the original 4096 channels
(0-4095) are generated in addition to the (convolved) spectra with 128/32 channels
from HIST/GRB data. Used only in SPEC mode.
- hkfile = hk.fits [filename]
- Input HK file name for GTI search. Required and used only in SCAN mode.
- hkext = HK_HXI1_APMU_PRM [string]
- HK extension name to read for the HK file. The name varies, depending on instrument. The parameter is required and used only in SCAN mode.
- (gticut_pre = 8) [integer]
- Duration [s] prior to times in the HK file that are used to compute the lower limit
of each GTI. Times in the HK file indicate the time of the lower discriminator
threshold change. Used only in SCAN mode.
- (gticut_post = 4) [integer]
- Duration after times in the HK file that are used to compute the lower limit
of each GTI. Times in the HK file indicate the time of the lower discriminator
threshold change. Used only in SCAN mode.
- (cleanup = yes) [boolean yes|no]
- Delete temporary files if 'cleanup=yes'.
- (clobber = no) [boolean yes|no]
- Overwrites the existing output file if set to yes.
- (chatter = 1) [integer 0|1|2|3]
- Chatter level for output. Set to 0 to suppress output,
or to 1, 2, or 3 for increasing the chatter of the output.
- (logfile = !DEFAULT) [string DEFAULT|NONE|file name]
- Log file name. If set to DEFAULT, uses the name of the task and, if
preceded by "!", overwrites the file if it exists. If set to NONE, no
log file is created.
- (debug = no) [boolean yes|no]
- Diagnostic output is printed to the screen if set to yes.
- (history = yes) [boolean yes|no]
- Records tool parameters in HISTORY.
EXAMPLES
- Create all light curves for HXI1 HIST data with a selection of energy channels.
hxisgdshield infile=HXI1_shield_data.fits outfile_root=lc outfile_type=LC datatype=HIST columnname=all \
hkfile=NONE hkext=NONE energybin="10-100"
- Create a spectrum and a deconvolved spectrum for HXI1 HIST data in
the SH_HIST5 column.
hxisgdshield infile=HXI1_shield_data.fits outfile_root=spec outfile_type=SPEC datatype=HIST columnname=SH_HIST5 \
hkfile=NONE hkext=NONE
- Create all SCAN light curves for SGD1 SCL data.
hxisgdshield infile=SGD1_shield_data.fits outfile_root=scan outfile_type=SCAN datatype=SCL columnname=all \
hkfile=hk.fits hkext=HK_SGD1_APMU_PRM
LAST MODIFIED